Intermediate neutron water kerma and flux measured between
1999. Okt. – 2000. Febr.

No Date Filter
mm
Circumstances Dose rate
mGy.s-1
Inc. Flux
n.cm-2.s-1
Refl. Flux
n.cm-2.s-1
Monitor
cps
1 X.18. 0 Bi
45Pb+10B4C
10 cm far from
B4C filter
0.087 1.75*105 - 17400
2 X.19. 0 Bi
45Pb+10B4C
Between B4C
filter and 3 cm
water
0.30 2.98*105 2.95*105 16900
3 X.19. 0 Bi
45Pb
On B4C filter 0.87 1.76*106 - -
4 X.25. 150 Bi
45Pb+10B4C
Between B4C
filter and 2 cm
water
0.007 9.57*103 5.18*103 2360
5 X.26. 0 Bi
100 plexi
On B4C filter 0.233 4.39*105 6.34*104 12400
6 X.26. 0 Bi
45Pb+100 plexi
On B4C filter 0.134 2.61*105 8.64*103 9600
7 XI.15. 50 Bi
45Pb+10B4C
On B4C filter 0.045 6.20*105 2.93*104 9000

Notes
Flux is given per unit lethargy, 1/E spectrum considered below 100 keV.
Dose: 0.5 eV - 100 keV, incident + reflected together.


Gamma dose measured between
1999. okt.- 2000. Febr.

No Date Filter
mm
Circumstances Dose rate
mGy.s-1
n/gamma Monitor
cps
1 X.18. 0 Bi
45Pb+10B4C
10 cm far from
B4C filter
0.087 5.31 17400
2 X.19. 0 Bi
45Pb+10B4C
Between B4C
filter and 3 cm
water
0.30 - 16900
3 X.19. 0 Bi
45Pb
On B4C filter 0.87 - -
7 XI.15. 200 Pb+20Fe
45Pb+10B4C
On B4C filter 0.045 16.1 600


Chapter 4/ page 12 of 17